A case of the implementation of the all-in-one card system in the office building of a group company
[ad_1]
Project Overview:
The newly-built office building of a certain group headquarters is an intelligent office building. According to the analysis of the network system requirements and network structure of the group’s office building, considering the large number of multimedia and support multi-service applications on the network, as well as the scale of network access users, High requirements for network performance. At the same time, factors such as network compatibility, expansion and performance-price ratio, as well as the implementation of triple play in the later period, are taken into account to enable the network to maintain its technological advancement for a long time. We use the “quartz optical fiber + plastic optical fiber” all-optical network access method to build the group’s office building network system.
The office building has 10 floors above ground and 2 floors underground, with a construction area of 42,000 square meters, including underground civil air defense areas, underground garages, exhibition halls, restaurants, offices, meeting rooms and other functional areas. It is a comprehensive office building; another building is built separately next to it There is a lecture hall with two floors and a building area of 1,650 square meters.
Design Principles:
The office building is constructed in accordance with the goals and requirements of the intelligent building, combining complete service facilities, advanced electromechanical equipment, modern office and communication systems, and intelligent management and control modes.
Give full play to the use functions of the main equipment in the building, integrate power supply, air-conditioning facilities, fire alarm, comprehensive security, access control system, etc. into a comprehensive unified system, and implement hierarchical distributed control, centralized monitoring and unified management.
With efficient and fast information communication processing function, it can detect and receive the content of major programs in the world at any time, and publish and exchange information, providing comprehensive and three-dimensional advanced communication methods and services.
Make full use of modern advanced technology and methods to create a safe, reliable, comfortable and efficient working and living environment inside the building, and provide an optimized place for work, life, entertainment and leisure.
The structured integrated wiring system adopts plastic optical fiber wiring in the building and complies with various design and installation standards. It provides an advanced, unified and reliable data, voice and video transmission platform to fully meet the needs of office automation and communication automation, and adapt to the future 10 The need for technological upgrading and application development during the year.
The system also has the functions of Internet, IPTV, and VoIP.
Using the GEPON+ plastic optical fiber LAN solution, data, voice, and TV are integrated into one network system to achieve “three networks in one.”
The entire integrated wiring system will fully embody the principles of advanced, practical, reliable, economical, open, expanded and modular, standardized and easy to maintain.
Overall design:
The following is a diagram of the system structure. The structure diagram is divided into three parts:
The first part is the central computer room. This part is the collection end of user terminal data. The main equipment placed is the core switch, server group, monitoring center and the core equipment OLT of the GEPON system. The main function of this part is to provide terminal users in the building. The data is collected and connected to the external network. Among them, the data part of the business is realized by connecting to the Internet through the core switch; the traditional analog voice part of the business is realized by connecting to the PSTN network through the voice relay gateway.
The second part is the floor part, where access equipment such as ONU and plastic optical fiber switches are mainly placed.
The third part is the office area, which is mainly used to realize the network connection of a variety of user terminal equipment (computers, telephones, IPTV, etc.). All user terminal signals are converted into data signals and gathered to the central computer room through GEPON equipment to finally achieve network integration .
Security monitoring subsystem:
Using a digital system, IP monitoring is implemented as follows:
In terms of the front-end camera placement, full careful consideration is made to enable the system to capture the target in the shortest time, so that the security personnel can grasp the situation on the spot in time, and detect and avoid sudden and vicious incidents. The specific design is as follows:
The underground garage is equipped with 12 dome cameras, 7 elevator car dome cameras, 4 dome cameras in the exhibition hall, 12 dome cameras in the restaurant, 24 dome cameras in the elevator halls of each floor, 56 dome cameras in the entrance and exit of each floor, and entrances and exits of the garage. A total of 2 wide-dynamic cameras are set up, 6 high-speed domes are set up on the perimeter of the building, a total of about 123 monitoring points are set up, matrix + hard disk video recorder system architecture, UPS integrated power supply. Set up an anti-theft alarm system, set up infrared detectors on the first floor of the building, set up double-check alarm detectors in important rooms, set up manual alarm buttons in the financial room and leadership rooms, set up door magnetic alarms, etc., which are linked with the monitoring system.
One card subsystem:
As a modern office building, all-in-one card management has become one of the indispensable weak current systems. Among them, garage access management, access control systems and consumer systems are widely used in modern buildings. According to the actual needs of the building, we set up all-in-one card points in key office areas and garages:
Note: The all-in-one card network uses plastic optical fiber wiring and connects to the plastic optical fiber switch.
We use the attendance management subsystem, access control management subsystem, consumption management subsystem, intelligent parking subsystem, and parking guidance subsystem in the one-card system in the office building of the group. In addition, the one-card system can also support elevator control, intelligent channel control, conference sign-in and other applications.
Access control subsystem:
The system adopts the internationally popular non-contact IC card access control system, which has high security, convenience and cost-effectiveness, is not easy to be copied, has a record of opening the door, and can monitor each door in real time and link with the security system. Compared with the traditional contact IC card, it has the advantages of high reliability and long life. The access control system is transmitted by plastic optical fiber through the TCP/IP Ethernet communication protocol, connected to the back-end plastic optical fiber switch, and communicates with the management center. In order to carry out data analysis, statistical reports, and attendance management.
Electronic Patrol Subsystem:
The patrol system is mainly used for the management of the security personnel in the office building of the group, requiring the security personnel to continuously inspect every important part of the office building of the group according to the patrol route to further strengthen the internal security management of the building and the internal management of the property company . In the case of a police situation, security personnel can rush to the scene as soon as possible, deal with relevant matters in time, and achieve an organic combination of civil air defense and technical defense.
This project designs 4 sets of patrol machines and 100 offline patrol points.
Parking lot management subsystem:
A comprehensive garage management system is installed at the entrance and exit of the underground garage in the office building. This system can carry out all-round management such as the parking of internal vehicles and temporary parking of foreign vehicles, automatic control of entry and exit, and analysis reports of garage operation conditions. System control host configuration: automatic brake lever and control chassis system, LED display screen.
Limited TV subsystem:
The cable TV of this project is mainly set up in canteens, cafes, tea rooms, boxes, elevator halls, meeting rooms, lecture halls and leadership offices, etc., and 230 cable TV potentials are set up.
The system uses 860M two-way adjacent frequency system to transmit the radio frequency signal output by the front-end computer room.
The office building is easy to expand to realize IPTV services based on the characteristics of network and digitization.
The partial implementation diagram of IPTV is as follows:
Concluding remarks:
With the development of information technology, especially the development of network technology, it is changing the way of information transmission, interpersonal communication and social management organization that people have formed for thousands of years, and profoundly affects social life and government Operation. The level of informatization has become an important indicator of a country’s comprehensive national strength, and the full realization of information sharing has become the consensus of all countries in the world. The integrated system of plastic optical fiber access network conforms to the trend of “light in and copper out”, and is a new generation of short-distance transmission system. As the basic architecture of the customer premises network, it supports various scenarios of FTTx and meets the requirements of “three networks in one” and integrated wiring of intelligent buildings. It can be used for both FTTH/FTTD in xPON mode or independent networking. National agencies, enterprises and institutions, cultural education, medical and health care, smart buildings, residential communities, industrial parks, schools, hospitals, hotels, Internet cafes, and security monitoring broadcasts and requirements for shielding and confidential lightning protection and other scenarios.