Bank double-door interlocking anti-following access control system solution

SaveSavedRemoved 0
Deal Score0
Deal Score0

[ad_1]

1. Application background and system overview

With the increasingly severe public security situation and the frequent occurrence of robberies and thefts, in real life, vicious cases of robbery of bank money-carrying vehicles are no longer unique in Hong Kong and Taiwan film and television works. How to deal with bank robbery and protect lives and property from loss is the most difficult problem that the existing bank security system faces directly. The bank double-door interlocking solution provided by our company minimizes various risks and has been widely adopted in many industries and departments, especially in the banking, securities, and postal industries. There have been many successful cases.

First, explain the concept of double door interlocking. The so-called double door interlocking linkage door means that two doors have the function of interlocking linkage, that is, when one door is opened, the other door will not be able to open, only when the two doors are closed, In order to open any of the doors. According to bank safety management regulations, two doors must be set up at the entrance and exit of cash counters such as savings outlets, and employees must lock the first door in accordance with the regulations after entering the first door to enter the second door, such as entering the first door. If the door is not closed as required, employees will not be able to enter the second door. The purpose of this is to prevent criminals from stalking and committing crimes.

Bank-promoted cases are usually criminals who use the method of trailing or coercing staff to enter the business hall to carry out criminal activities. No matter which method the criminal adopts, in order to enter the business hall, he must first pass one or two passes. Security doors, how to prevent crimes, the key lies in how to well control the security door access permissions and quickly communicate the police information to the security department or the public security department. The Shiwo brand two-door interlocking access control launched by Zhaoketai Company has an ingenious design for controlling safe passage doors. It is aimed at criminals who use trailing or coercive methods to enter the business hall for illegal activities, and specializes in research A kind of access control security controller.


Bank anti-tailing (double-door interlocking) access control system solution

2. Detailed explanation of several main functions

1. Linkage (or double door interlock) function: if one door is not closed, the other door will never be opened
For example: the outer door is not closed, the voice prompt: please close the outer door, the password keyboard reader or exit button of the inner door is invalid, and the door cannot be opened; the system must wait for the password keyboard reader or exit button of the inner door after the outer door is closed. Only with a response can the inner door be opened.
On the contrary: the inner door is not closed, the voice prompt: please close the inner door. The password keyboard reader or exit button of the outer door is invalid and the door cannot be opened; the system must wait until the inner door is closed before the password keyboard reader or exit button of the outer door responds before opening the outer door.

2. Anti-tailing (or duress alarm) function, each card reader can alarm
1 set of clear alarm password: enter the clear alarm password, the system will output a clear alarm signal (that is, the clear alarm relay is activated), and both doors will be locked at the same time when an alarm occurs! This alarm can only be released by the linkage key of the indoor 5-key keyboard to make the system return to normal working status.
1 set of dark alarm password: input dark alarm password, the system will output dark alarm signal (ie: dark alarm relay action), both doors will be locked at the same time when alarming! This alarm can only be released by the linkage key of the indoor 5-key keyboard to make the system return to normal working status.

3. Illegal user alarm function. If there are 5 illegal users in a row, the sound and light alarm will send out an alarm signal, and the system will automatically lock for 5 minutes, then return to normal, or use the linkage key to return to normal.

4. The voice prompt function prompts the user: the outer door has been opened, the inner door has been opened, the door has been fully opened, the door has been fully locked, please close the inner door, please close the outer door and other door status information.

5. Channel light control, the power of the external channel light is less than 400W, it will light up when the door is opened, and it will automatically go out after one minute.

7. Emergency braking (double doors fully locked) / double doors fully open function.

8. Special functions of five buttons (five-key keyboard)
Fully open: Press the full open button, the system will make the two doors in a fully open state. Voice prompts the user: the door is fully open. After the two doors are opened for 5 seconds, it will automatically reset, and the system will return to the normal working state (if one door is open, the full open key will also work).
Full lock: Press the full lock button, the system keeps the two doors in full lock state. Voice prompts the user: the door is fully locked. When the two doors are fully locked, the password keyboard of the outer door, the inner door, and the exit buttons beside the two doors are all disabled, and the two doors cannot be opened. Only through the linkage button to release, the system returns to the normal working state.
Linkage: Press the linkage button to make the system return to the normal working state from the full lock function state, the illegal user alarm function state, and the full lock state after the duress password alarm (open or dark password alarm).
Open the inner door: press the button to open the inner door, and the user will be prompted by voice: the inner door has been opened. (It is equivalent to the exit button of the inner door, which must be linked, that is, when the inner door is opened, the outer door cannot be opened)
Open the outer door: press the button to open the outer door, and the user will be prompted by voice: the outer door has been opened. (It is equivalent to the exit button of the outer door, which must be linked, that is, when the outer door is opened, the inner door cannot be opened)
Note: The above door open refers to the state of the door lock, not the state of the door

9. There are many ways to open the door: ①Swipe card, ②Password, ③Swipe card+password, ④Card or password, ⑤Exit button.

10. Initialize the management password function
Initialization method: There is a reset button on the controller main board (see the hardware wiring diagram), hold it down before powering on the system, and the system is powered on. After the three lights on the system mainboard flash at the same time for a few seconds, the mainboard buzzer will sound once, and the keys can be released to complete the initialization of the management password. The management password after initialization is: 88888888;

12. The unlocking time is 5 seconds when leaving the factory, which can be set by programming; after the user’s identity is confirmed, the door lock opens for 5 seconds and waits for the personnel to open the door. The system voice prompts: the inner door has been opened / the outer door has been opened.

13. The door sensor alarm time is 5 seconds before leaving the factory, which can be set by programming; the door is locked 5 seconds after the door is opened, but if the door sensor detects that the door is not closed, the system prompts: please close the inner door/please close the outer door.

3. Introduction/installation of main equipment

A standard double-door interlocking access control system includes the following equipment: 1 set of access controllers, 2/4 password readers, 2 electric locks + door sensors, 2 exit buttons, 5 function buttons, 1 sound Light alarm and 1 corridor light etc.
1. Access controller: including access control board, power supply board, transformer, battery, light control relay module, speaker, etc.;
Controller iron box size: 285 x 246 x 83 (material is 1.0 steel sprayed plastic); power output: 25W; battery: 4AH; main control board power consumption (linked standby state) <3W; speaker: 0.5W/8Ω, Installed in the sales department or on the ceiling of the aisle.
2. The five-key keyboard and sound and light alarm are generally installed in the sales department.
3. The outer door part has the following equipment: a password reader; an exit button, a pair of door sensors, an electric lock, and a lock power supply
Password card reader size: 106 x 86 x 35mm, shell material ABS injection, keyboard keys used> 100,000 times, card reading distance: 10-15cm.

4. The inner door part has the following equipment: a password reader, an electric lock + door sensor, and a button to open the door.
5. Wire selection, card reader line: It is recommended to use 8-core shielded multi-strand twisted-pair network cable between the card reader and the controller port (three cores are spare, if you don’t need the reader’s sound and light feedback, the legal card is not required. Connect the buzzer line), the data line Data1 / Data0 are twisted pair each other, the wire diameter is recommended to be 0.5 square millimeters or more, and the longest can not exceed 30 meters, and the shielded line is connected to the GND of the controller;
For the electric lock, please use the special anti-tailing motor lock (also known as the spiritual lock) for the bank, and use the power cord of AVR 0.5mm² or more.
For other equipment connection, it is recommended to use a two-core wire with a wire diameter of 1.0 square millimeter or more.

4. How to use the access control system

1. The use of the code readers for the outer door 3 and 4 and the card readers for the inner door 1 and 2
First, set the door opening mode of the inner and outer doors according to the user’s requirements,
Set the user card and password to open the door,
The user swipes the card or enters the password on the card reader, the card reader buzzer beeps once, effective, the system opens the electric lock, at the same time the channel light is on, it will automatically go out in one minute, and the voice prompt: the outer door has been opened / the inner door has been opened, The user can push the door to enter. The unlocking time can be set.
If the user is invalid, the card reader buzzer will beep twice and the door will not be opened.

2. Use of the outer door exit button and the inner door exit button
When going out of the inner or outer door, press the exit button beside the door, and the channel light will be on at the same time, and it will go out automatically in one minute. Personnel can push through the door. The door opening delay can be set.

3. Use of five-key keyboard and alarm
The five functions of the five-key keyboard: full open, full lock, linkage, open inner door, open outer door
The use of the alarm, when there is an unexpected situation, such as the bad guys following, and the staff opens the door under duress, you can enter a set of open alarm password or dark alarm password to call the police.
Note 1: Double-door interlocking means: one door is not closed and the other door cannot be opened.
Note 2: After the user opens the door, it must be closed within the specified time (the time for closing the door is specified, that is, the door sensor alarm time can be set), otherwise, the user will be prompted by voice: Please close the outer door/please close the inner door.
Note 3: If there are 5 illegal users in a row, the system will alarm, and the system will automatically lock for 5 minutes, and then return to normal, or use the linkage key to return to normal

Five, the basic parameters of the system

Number of management doors: 2
Card reader interface: 4
Exit button: 2
Electric lock control: 2
Door opening time: 0.1-25.5 seconds
Door sensor input: 2 channels
Alarm output: 2
Alarm response time: 0.1-25.5 seconds
Fire input: 1
Battery protection data retention time after power failure: more than 10 years.
Chassis appearance
Dimensions: 285mm ×240mm×82mm
Colour: Black
Weight: about 3000 grams
Motherboard appearance
Size: 195mm×125mm×1.6mm
Color: dark blue
Weight: about 310 grams
working environment
Temperature: <60℃
Humidity: 10% ~ 95% RH
Rated voltage: DC12V
Rated current: <0.2A
Rated power: ≤5W

1

[ad_2]

We will be happy to hear your thoughts

Leave a reply

RFID made in China
Logo
Enable registration in settings - general
Compare items
  • Cameras (0)
  • Phones (0)
Compare