Network Access Control Solution
[ad_1]
All-in-one independent access control system The card reader is integrated in the controller; the all-in-one is installed outside the door
Split independent access control system The card reader is separated from the controller, the card reader is installed outside the door, and the controller is installed inside the door
Small networked access control system Adopt single door and multi-door controller, network with computer, 485 bus connection
Local area network small networked access control system Connect the access control controllers in each area to the local area network through a TCP/IP converter
Large-scale network access control system using SK800 eight-door network controller, directly connected to the computer via TCP/IP
(1) Integrated independent access control system
System composition:
1. SK100E or SK100M access control integrated machine (depending on the card used to choose the correct model. SK100E uses EM card, SK100M uses Mifare model)
2. Cards (EM cards or Mifare cards, EM cards are divided into thick and thin cards, Mifare cards only have thin cards)
3. Electric lock
4. Dedicated power supply for access control
5. Exit button
6. Shielded twisted pair
Features:
1. Simple installation and construction. The access control integrated machine contains two parts of the card reader and the controller, so there is no need to connect the card reader and the controller through a shielded wire.
2. A variety of door opening methods.The access control integrated machine itself has three door opening methods: card opening, password opening and password + card opening, no need to configure a key reader
3. Card issuance, card deletion and other operations can be completed through the access control integrated machine, which is simple and practical
4. Suitable for installation in occasions where safety requirements are not high, such as an office in a building
5. According to needs, an external Wiegand card reader can be used to open the door by swiping the card.Therefore, in the actual project, the access control integrated machine can also be installed in the door, and the external card reader is installed outside the door, so that both entry and exit can be swiped
Installation diagram
620)this.style.width=620;” border=0>
620)this.style.width=620;” border=0>
(2) Split and independent access control system
System composition:
1. SK100 single door controller
2. Card reader (depending on the card used, choose the correct card reader model, such as EM card choose EM card reader, Mifare card choose Mifare card reader, especially note that the single door controller can only be connected Wiegand card reader, 485 card reader is not allowed)
3. Cards (EM cards or Mifare cards, EM cards are divided into thick and thin cards, Mifare cards only have thin cards)
4. Electric control lock
5. Dedicated power supply for access control
6. Exit button
7. Shielded twisted pair
Features:
1. Compared with all-in-one access control, it has higher security.The card reader is installed outside the door, and the single-door controller is installed inside the door
2. Card issuance, card deletion and other operations can be completed through a single-door controller, which is simple and practical
3. A Wiegand card reader can be connected as needed to open the door by swiping the card
4. Suitable for installation in places with low safety requirements, such as offices in buildings
Installation diagram
620)this.style.width=620;” border=0>
(3) Small networked access control system
System composition:
1. The controller, which can be an all-in-one access control machine, a single-door controller, a two-door controller or a four-door controller
2. Card reader (depending on the card used, select the correct card reader model, such as EM card choose EM card reader, Mifare card choose Mifare card reader, pay special attention to the single door controller and access control integrated machine Can only be connected to Wiegand card reader, not 485 card reader)
3. Access control management software
4. 485 converter
5. Card (EM card or Mifare card, EM card is divided into thick and thin card, Mifare card only has thin card)
6. Electric lock
7. Dedicated power supply for access control
8. Exit button.
9. Card issuer SKRD-EM/K2 or K3; when using Mifare card, the card issuer model is SKRD-MI/K2 or K3
10. Shielded twisted pair
Features:
1. The controller is connected to the computer to facilitate real-time monitoring of personnel entering and exiting in each door zone, even if the alarm event is mastered
2. Modular operation, convenient for system setting, card personnel management, access data printing and attendance management
3. Quickly perform process control settings and automatic DI/DO settings, making the access control system truly a highly intelligent management system
4. Suitable for installation where safety requirements are high, especially where real-time monitoring of the entry and exit of personnel in each control door area is required
Installation diagram
620)this.style.width=620;” border=0>
(4) Small-scale networked access control system for local area network
1. The controller, which can be an all-in-one access control machine, a single-door controller, a two-door controller or a four-door controller
2. Card reader (depending on the card used, choose the correct card reader model, such as EM card choose EM card reader, Mifare card choose Mifare card reader, pay special attention to single door controller and access control integrated machine Can only be connected to Wiegand card reader, not 485 card reader)
3. Access control management software, can be stand-alone version or online version
4. TCP/IP converter
5. Card (EM card or Mifare card, EM card is divided into thick and thin card, Mifare card only has thin card)
6. Electric lock
7. Dedicated power supply for access control
8. Exit button.
9. Card issuer SKRD-EM/K2 or K3; when using Mifare card, the card issuer model is SKRD-MI/K2 or K3
10. Shielded twisted pair (used for 485 bus communication)
11. Serial port virtual program
12. Door sensor
Features:
1. Through the TCP/IP converter, the access controller can communicate with the computer without wiring
2. Provide serial port virtual program, no need to change system software
620)this.style.width=620;” border=0>
(5) Large-scale network access control system
System composition:
1. SK800 eight-door network controller
2. SKDC door controller
3. Card reader (depending on the card used, select the correct card reader model, such as EM card choose EM card reader, Mifare card choose Mifare card reader, pay special attention to the single door controller and access control integrated machine It can only be connected to Wiegand card reader, not 485 card reader). When the SK series universal card reader is used alone, the SKDC door-side controller can be omitted and directly connected to the SK800 network controller. The electric lock, door sensor and exit button are directly connected to the universal card reader.
4. Access control management software, can be stand-alone version or online version
5. Card (EM card or Mifare card, EM card is divided into thick and thin card, Mifare card only has thin card)
6. Electric lock
7. Dedicated power supply for access control
8. Exit button
9. Card issuer SKRD-EM/K2 or K3; when using Mifare card, the card issuer model is SKRD-MI/K2 or K3
10. Shielded twisted pair (used for 485 bus communication)
12. Door sensor
Features:
1. The SK800 controller can directly communicate with the computer through the TCP/IP network, without the need for a TCP/IP converter
2. 100,000 cards and 100,000 records.It is one of the largest and fastest network controllers in the world
3. Super user card function makes the system more safe and reliable
4. PLC function, system linkage is more convenient and quick
5. Suitable for installation in high-end buildings with high safety requirements, many personnel, and many controlled door areas
Please click[SK800控制器专栏介绍]