Chapter 1 Introduction to the management of fire access doors by the access control system

  1.1 Project situation

Shenzhen XX Building Company’s existing 58 fire access doors need to be managed in a unified way. It is required to be normally closed and open automatically when there is a fire alarm. If there is an illegal door opening, the management center can report to the police in time and accurately remind that the door is abnormal. The management personnel can open the door normally through an authorization card when entering and exiting, and the management center has a record of opening the door.

 1.2 Solution

It is recommended to use the access control and magnetic lock supporting system to manage all fire access doors in a unified manner. Each fire exit door is equipped with a card reader inside and outside, a 280KG tension magnetic lock (500KG tension magnetic lock can also be installed if you have special needs), and a controller is connected to the management center.

 1.3 The advantages of the access control system to manage fire access doors

It is possible to establish a standardized management image for companies, buildings or offices, improve the management level, and standardize the internal management system at the same time.

A proximity card can replace all the keys to the fire exit locks, and has different passing permissions, and the inspectors are authorized to enter the doors within their scope of responsibility with the card. All incoming and outgoing situations are recorded in the computer, which is convenient for inquiring about the time of specific events and fulfilling responsibilities.

Non-inspectors or authorized personnel can be shut out. For example, it is possible to prevent salespersons in industries such as pyramid schemes and insurance from entering the building without permission through the fire exit, which interferes with the normal office order of the building. If there is an illegal intrusion or man-made damage to the fire door and the magnetic lock is damaged, the management computer of the management center can immediately report to the police, and accurately report which door is abnormal, and the management center can immediately notify the relevant personnel to check.

If an employee’s proximity card is lost, it can be reported in the system immediately, so that even if someone else finds the proximity card, they cannot enter the company. This is much more convenient than ordinary fire escape locks. You don’t have to change the lock for safety reasons. The doors are rekeyed. The induction card of the staff who resigned, fired, or left is written off. The employee will not be able to open the fire door with the original authorization card in the future. If you do not adopt the induction card access control management method, you may have to do more just in case. Replace the fire door lock again.

Using advanced international internal encryption protocols, outsiders cannot open your electric locks to enter your premises by mechanical or other high-tech methods. Others, such as password access control and mechanical locks, have no corresponding safety mechanism, and you can easily enter your place through a short circuit or a master key.

The system can be fully turned on automatically in the event of a fire, which meets the fire protection requirements. Mandatory software operations can also be performed. For example, all fire doors are required to be opened during routine inspections. You can open all fire doors through software functions, and restore the system to normal through the software after the inspection is completed.

It can monitor the status of the door and the entry and exit status of the card holder in real time, and can compare and display photos to prevent illegal holders from pretending to enter.

1.4 Introduction of CASTRO access control system

A. Introduction to product hardware performance
Model: FX01
Product Features:
CASTRO series access controllers adopt advanced technology, use large-scale integrated circuit CPLD and high-speed industrial microprocessor MCU design methods, compact structure and good stability. The product has passed the performance and quality test of the Ministry of Public Security of the People’s Republic of China, and is used in many important places. FX01 single door access controller is an important part of CASTRO series access control system. It can control two-way card reading of a single door. Through the RS485 bus, a single bus can form a control network of 256 FX01, which can manage up to 256 door points. It can also be networked with FX02, FX04, two-door and four-door access controllers to realize data and resource sharing at the same time. Each controller can work independently and is not affected by the shutdown of the management computer. When the computer is connected, all data is uploaded to the computer through the management software, and all transaction records and data are stored when offline.

The FX01 intelligent access control controller has a powerful internal point interlocking function in the board. The interlocking of each point in each control board can be set arbitrarily to mutually restrict each other and improve security. It is especially suitable for banks, institutions and other places with high security requirements. .
FX01 single door access controller has auxiliary input and output points, which can be connected to analog or digital, switch status signals such as smoke and humidity, and can control lighting, CCTV, fire alarm and other equipment, and can realize various linkage functions.

Product parameters:
Strong compatibility: suitable for various WG26 protocol card readers and biometric devices such as MOTOROLA, HID, TI, EM, MAFARE, etc.;
Legal card capacity: 3000 / 12000;
Offline card swiping records: 24000;
Buttons, alarm time records: 8000;
Communication mode: RS485 and RS232 are optional;
A set of standard door status input terminals: 1 way door sensor;
Two sets of standard alarm status input terminals: 2 alarms;
One set of exit request button input terminals: 1 exit button;
Two groups of C-type electric lock relay output terminals: 1 group with 2 normally open and normally closed active outputs, 1 group with 2 normally open and normally closed passive outputs;
Two groups of C-type alarm relay output terminals: 1 group with 2 normally open and normally closed active outputs, 1 group with 2 normally open and normally closed passive outputs;
Eight-bit controller address setting jumper;
Input parameters: dry node switch input;
Working environment: temperature -40℃~70℃, humidity 0~90%;
Output load parameters: working voltage AC≤220V, DC≤24V, working current≤10A;
Working power supply: rated voltage AC220V (50/60HZ), rated current <0.2A;
Card reader interface: WG26 format;
Card reader connection line: 5-core 0.5mm shielded wire, 24AWG, the longest 100 meters;
Use 5.08 pitch detachable terminal block, alloy steel non-magnetic flange material;
Outer box material: 1.5mm steel plate.

B. The composition of the access control system
Card reader: Recognize the built-in encrypted card number of the proximity card through the principle of radio frequency induction.

Proximity card: Store the user’s ID number that cannot be copied and decrypted.

Access control controller: stores the access card permissions and card swiping records, and centrally processes all card readers upload signals, is responsible for coordinating with computer communications and other data storage, and the intelligent processing center that cooperates with management software.

Magnetic lock: Fire exit door switch actuator.

Communication converter: for networking and long-distance communication of all controllers.
Management software: Centrally manage and monitor all units through a computer, and perform corresponding clock, authorization, and statistical management.
Door open button: Go out can be set to press the button to go out. If going out is not restricted, an exit button can be installed inside the fire exit door, which can save the cost of a card reader.
Power supply: Provides power supply for system operation power and execution structure of electric lock.
Schematic diagram of access control management fire exit door

C. Schematic diagram of the wiring and communication mode of the access control system.

Note: The above pictures include the access controller networking pictures of 485 and TCP communication modes.

Chapter II Design Principles and Basis Specifications

 2.1 Design principles

Due to the need for security and high-efficiency management, the design of the access control system should follow the following principles:

Practicality of the system
The function of the access control system should meet actual needs, not flashy. If one-sided pursuit of the advancement of the system will inevitably result in excessive investment and deviate too far from actual needs. Therefore, the practicability of the system is the first principle that should be followed. At the same time, the system’s front-end products and system software have good learnability and operability. Especially the operability (convenience), so that managers with basic computer operation level can master the operation essentials of the system through simple training, and reach the level of operation that can complete the duty task.

System stability
Since the access control system is an uninterrupted and long-term work system and is closely related to our normal life and work, the stability of the system is particularly important. The product system is required to have more than five years of successful application experience in the market, with a corresponding customer base and customer service system.

System security
While all the equipment and accessories in the access control system operate safely and reliably, they should also comply with relevant Chinese or international safety standards, and can work effectively in non-ideal environments. The powerful real-time monitoring function and linkage alarm function fully guarantee the safety of the user’s environment.

System scalability
The technology of the access control system continues to develop, and the needs of users are also changing. Therefore, the design and implementation of the access control system should take into account the actual needs of future expansion, that is: it can flexibly increase, decrease or update each subsystem to meet the needs of different periods of time. Need to maintain a leading position for a long time and become a model of intelligent buildings. When the system is designed, a reasonable configuration is made for the functions that need to be realized, and this configuration can be changed, even after the completion of the project, the change of this configuration is possible and convenient. The system software will be upgraded and perfected according to the market demand of the developers in different historical periods, and the software will be upgraded for the corresponding application customers. At the same time, it can be extended to all-in-one card projects such as the attendance system, conference sign-in system, patrol management system, and dining management system.

Easy maintenance of the system
The maintenance of the access control system during operation should be as simple and easy as possible. The operation of the system is truly to the extent that it can work when the power is turned on, and it can be operated when it is plugged in. And there is no need to use too many dedicated maintenance tools during the maintenance process. From the configuration of the computer to the configuration of the system, the configuration of the front-end equipment has fully considered the reliability of the system. And implemented the corresponding certification. While achieving the lowest system failure rate, we also take into account that even when problems occur due to unexpected reasons, we ensure the convenient storage and rapid recovery of data, and ensure that the channel can be opened quickly in an emergency. The maintenance of the entire system is online, and the normal operation of all equipment will not be stopped due to the maintenance of some equipment.

Advanced
Under the premise of ensuring stability, practicality and convenience, access control products should have a certain degree of advancement to ensure that they will not be eliminated in the next few years, and can meet the requirements and needs of access control in use.

  2.2 Main design basis specifications

1. “International Generic Cabling Standard” ISO/IEC11801
2. “Code for Electrical Design of Civil Buildings” JGJ/T 16-92
3. “The People’s Republic of China Security Industry Standard” GA/T74-94
4. “People’s Republic of China Public Safety Industry Standard” GA/T70-94
5. “Engineering Technical Code for Monitoring System” GB/50198-94

  Chapter 3: Quotation of XX Building Fire Exit Door Management Product

Shenzhen Golden Card Technology Co., Ltd.
Deng Wenzhi
Phone: 0755-28188731 13926574852
Fax: 0755-28188732
Mail:[email protected]

1

[ad_2]

We will be happy to hear your thoughts

Leave a reply

RFID made in China
Logo
Enable registration in settings - general
Compare items
  • Cameras (0)
  • Phones (0)
Compare