Xinzhongxin Golden Dragon Card Intelligent Water Control Management System Solution

SaveSavedRemoved 0
Deal Score0
Deal Score0

[ad_1]

King Long Card Water Control System (V2.1) version is for the vast number of small and medium enterprises and institutions, mainly used to control the water management system of public bathrooms, apartment bathrooms and boiling water rooms. The system targets a broad group of Golden Dragon Card users. According to the funds in the Golden Dragon Card, the system records and controls the use of Golden Dragon Card users for bathing and opening water in real time, which is of great significance for enterprises and institutions to strengthen resource management and cost accounting. The King Long Card Water Control Charging System is easy to operate and has a friendly interface. It mainly has the following functions:

1. The system can adapt to the needs of users with a variety of water control modes, such as apartment bathing, boiling water room water, public bathrooms, etc. For different water control modes, water controllers (such as timing and metering) and management parameters can be set for different management methods ( Basic water price, etc.), with strong versatility and adaptability.

2. The system adopts hierarchical management for the management of the water controller, and there are two-level management machines under it. The operating efficiency of the water control business system has been improved. In terms of business group management, a two-level business group has been set up to facilitate the analysis of the water control business situation and the management of the water control device.

3. The system is more flexible in the management of the operating water price of the water control business, and the operating water price can be set according to the different identities of consumers and the consumption situation of different water control modes.

4. The system operates in a 24-hour operation mode, which monitors the running status of all water controllers in real time, and can flexibly control the status of the water controllers—locking and unlocking the water controllers in batches. During the business process, the operator transfers shifts without stopping the system.

5. System account management functions such as account query, card issuance, account opening, account withdrawal, loss reporting, unlinking, card replacement, modification, error correction, subsidies and other operations. In addition to account information, account query can also query the account’s business transaction flow and deposit subsidy operation flow during the selected time period. The system provides individual and batch two methods to facilitate user operation.

6. The water control system has two operation modes: independent operation and connected with rice selling system. When the system is running independently, the account management is all effective. If it is connected to the sixth-generation meal-selling system, the account management work and the system parameters and business deposit functions related to account management and maintenance are all performed by the six-generation meal-selling system. The water control system only realizes the account query function and records all the business transaction flows sent to the sixth-generation system. The water sales transaction flow is uploaded to the sixth-generation Golden Dragon card rice sales system in real time to realize the all-in-one card.

7. The system’s business statistical analysis function includes statistical analysis of consumption and deposits by individual; consumption and deposits by department; consumption and deposits by identity; all business consumption and deposits by unit; and business status by business teams. Statistical reports can be output in detailed and summary form. The above statistical analysis includes daily, weekly, monthly, and special statistical reports for any period of time.

8. Data management functions include database backup and recovery, with automatic backup functions. Automatically clean up expired transaction data to improve the efficiency of the system during long-term operation.

9. The system operator has strict operating authority and operating range settings, and has audit and query functions for important system operation logs.

10. Use the card to control the water supply valve switch, insert the card to discharge water, and remove the card to cut off the water, which is convenient and quick.

11. The card reading display part is installed separately from the valve meter, which is convenient for the user to insert the card and check the balance.

12. Complete safety measures, which can record the number of various illegal attacks, and lock the valve if necessary, such as opening the shell, using strong magnetic interference, disconnecting the flowmeter, inserting an illegal card, leaking, etc.

13. Both the POS machine and the valve are supplied with a safe voltage and use a dedicated power supply. The voltage at the water supply site is 12V, so there is no electric shock hazard.

Topology diagram of water control system

(1) The main body of the system

1. Microcomputer.

The built-in “Golden Dragon Card Water Control System” software is used for parameter management of the water control system; card information management; various report management; operator information management; database management, etc.

2. Water controller.

The main function of the water controller is to control whether to supply water and billing during the water supply period. Specifically, it reads and verifies card information; displays working status and information; is responsible for communication with intelligent cascade devices and systems; manages and controls execution devices; stores and memorizes water transaction information; water controller and system communication adopt RS-485 communication . The water controller adopts anti-drain and splash-proof design as a whole. The water controller adopts isolated DC low-voltage power supply to ensure safe use.

The water controller can only read one type of card, and the water controller model should be selected according to the type of card used by the user.

The timing type water controller is charged according to the time of opening the valve to supply water, and the meter type water controller is charged according to the amount of water flowing through. The cost of the timing water controller is lower than that of the metering type, and the billing accuracy is relatively low.

3. Universal charge card reader.

The main function of the universal charge card reader is to read and verify card information for registration, inquiries, and purchase of water charges.

There are different models of universal charge card readers, corresponding to different card types. The card type used should be the same as that of the water controller.

4. The first-level management machine.

The main function of the first-level management machine is to transfer data, working status, and work instructions of the water control system, and to exchange data with the computer; and to transfer data to the second-level management machine. RS-232 serial communication is used for communication with computer; RS-485 communication is used for intelligent cascade or secondary management machine.

When the number of system water controllers is less than 100, it can be directly driven by the first-level management machine, and the second-level management machine is not used.

5. Secondary management machine.

The main function of the secondary management machine is to adopt a hierarchical structure to solve the contradiction between RS-485 machine quantity and response speed. The second-level management machine can perform water control system data transfer, working status transfer, work instruction transfer, water-controller communication management, and data exchange with the first-level management machine. RS-485 serial communication is used with the first-level management machine; RS-485 communication is also used with the intelligent cascade device.

When the number of water controllers is greater than 100, a second-level management machine is added, and the second-level management machine adopts a dial switch to set the management machine number. The number ranges from 01 to 60, and the secondary management machine in a system must not have duplicate numbers.

6. Intelligent cascade device.

The main function of the intelligent cascade is to isolate the communication, improve the communication load capacity, determine the working status of the communication line, and provide a low-voltage safe DC power supply for the water controller. The communication input and communication output of the intelligent cascade are RS-485, the power input of the cascade is AC220V, and the output is DC12V2A isolated DC.

7. Four-way transfer box.

The main function of the four-way adapter box is to connect the communication line of the system and the water controller to ensure the long-term stability of the wiring head. Generally, the water controller works in harsh environments (high temperature, high humidity, splashing), so the four-way junction box has a waterproof design.

8. Number card.

The function of the number card is to set a specific number for the water controller for the system to distinguish and manage. The “+, -” number card can adjust the opening amount of the valve, so as to control the size of the water flow, so that the different water outlets are as balanced as possible. The number card is composed of 12 cards from 1, 2, 3 to 9, 0, +, -.

The type of the number card should be the same as the type of card used by the water controller.

When the water controller is locked, using the number card will not change the machine number, but can be unlocked. The machine number can be changed after unlocking.

Note: The EM card water controller uses the photoelectric number card to set the number.

9. Base table

The base meter currently used is an integrated water meter with a valve. The main function is to measure the flow of water flowing through; visually display and transform the flow signal into an electrical signal through a signaling device to provide intelligent remote measurement and control; close or open the valve through the actuator to achieve the ultimate goal of controlling the flow of the pipeline. The control signal of the valve is provided by the water controller.

10. Valve

The main function of the valve is to control the on and off of the water flow to achieve the purpose of billing and water cut without money. When the pressure of the pipeline does not change or the pressure does not change much, the water flowing through the pipeline is proportional to the water passing time. The purpose of controlling billing is achieved by controlling the time of opening and closing the valve. The control signal of the valve is provided by the water controller, and the valve is driven by the motor deceleration mechanism.

Performance

software:

1. The system account department can be set to three levels, and the number of direct subordinate departments of each level department is up to 99.

2. There are 128 types of system account identities at most.

3. The system can manage up to 8 forms of water use such as apartments, public baths, and boiling water rooms. The nature of water control can be divided into two types: timing and metering.

4. The system can be equipped with a first-level management machine, the second-level management machine can be equipped with up to 60 units, and each second-level management machine can be equipped with up to 100 water control POS machines. The system is equipped with up to 6000 water control POS machines.

5. The maximum account capacity is 1 million people. 6. The minimum billing accuracy of consumer transactions is 0.001 yuan (0.1 points).

7. The single maximum consumption amount is 65.53 yuan (the valve will be automatically closed when exceeded, but the next transaction can be continued by pulling out the card and reinserting it).

8. All reports in the system are output on standard A4 format paper.

hardware:

Water controller

1. Working voltage: Working voltage of water controller: DC 8.5~20V

2. Working current: the maximum working current of the water controller is 200 mA

3. Card reading time: the response time of water controller reading card is less than 3 S

4. Power-on self-check function: The water controller has self-check functions such as memory, single-chip microcomputer, communication, and monitoring version.

5. Machine number setting: the maximum effective machine number range of the water controller is 0002~6099.

6. Data communication: The water controller and the intelligent cascade device adopt RS-485 communication.Communication rate 28.8k baud rate

7. Power-off valve shut-off function: When the valve is opened, the system power is turned off, and the water controller automatically closes the valve.

8. Offline working function: The water controller can work offline, that is, it does not work on the Internet, but for the apartment type, it only applies to the last 7 cards used on the water controller.

9. Failure alarm: valve failure, small balance alarm, communication failure alarm, illegal card alarm and other functions.

Smart cascade

1. Output voltage

No-load voltage: DC less than 20V

Full load voltage: DC not less than 12V

2. Output current. Maximum output current: 2A

3. RS-485 communication rate.Communication rate: 28.8K baud rate

4. Multi-level cascading load capacity: the intelligent cascade can be cascaded up to 3 levels.

5. Communication status indication: When the outlet of the smart cascade is short-circuited or embedded, the flashing frequency of the indicator light will increase.

6. Communication load capacity: RS-485 communication load capacity is 128 water controllers

7. Communication distance: The RS-485 communication distance of the intelligent cascade is not more than 1200 meters

8. Power load capacity: The power load capacity is 12 water controllers

9. Power supply distance (at full load): The power supply distance with full load is not more than 60 meters. (RVV 4×1mm2)

10. Intelligent cascade power supply: 220V±10%, 50Hz less than 40VA

11. Insulation strength: not less than AC 3000V between 220V power supply and 12V power supply,

Level 1 management machine

1. Communicate with the host computer

a. RS-232C serial communication is used between the management machine and the computer.

b. The communication distance is not more than 3 meters.

c. The communication rate is 28.8K baud rate

2. Communication with the lower computer: RS-485 communication is adopted between the first-level management machine and the second-level management machine.The communication rate is: 28.8K baud rate

3. Communication distance: the maximum communication distance is 1200 meters

4. Communication carrying capacity: the first-level management machine can carry 64 second-level management machines.

5. Power supply for the first-level management machine: 220V±10%, 50Hz less than 5VA

6. Insulation strength: no less than AC 3000V between 220V power supply and communication line

Secondary management machine

1. Communication with the host computer: RS-485 communication is used between the second-level management machine and the first-level management machine.The communication rate is 28.8K baud rate

2. Communication with the lower-level machine: RS-485 communication is used between the secondary management machine and the intelligent cascade.The communication rate is: 28.8K baud rate

3. Communication distance: the maximum communication distance is 1200 meters

4. Communication carrying capacity: The management machine can carry 32 intelligent cascades.

5. Power supply for secondary management machine: 220V±10%, 50Hz less than 5VA

6. Insulation strength: no less than AC 3000V between 220V power supply and communication line

7. Number range: The number range of the secondary management machine is 1-60, 6-digit binary code.

8. Simulation debugging tooling function: Before the system is installed, the 7th and 8th digits of the secondary management machine can be coded and used as debugging tooling. Dial ON at the 8th position and OFF at the 7th position, with a metered water controller available. On the contrary, the 8th bit is turned OFF and the 7th bit is ON, indicating the timing type. Note that when it is officially used, the 8th and 7th bits must be kept in the OFF position, otherwise free water will be used.

Miniature electric valve

1. Valve working pressure: The working pressure of the electric miniature valve is less than 1MPa,

2. Valve operating voltage. DC 3.6V~5V

3. Valve working current: less than 80mA when the voltage is 5V

4. Valve opening time: When the working voltage is 5V, the time from closed state to fully open state is less than 5 seconds.

5. Valve closing time: When the working voltage is 5V, the time from open state to fully closed state is less than 5 seconds.

6. Working medium temperature: less than 100 degrees

Controllable water meter

1. Water meter and valve pressure test: working pressure is less than 0.6MPa

2. Working voltage of water meter valve motor: DC 3.6V~5V

3. Working current of water meter valve: less than 120mA when the voltage is 5V

4. Valve opening time: When the working voltage is 5V, the time from the closed state to the fully open state is less than 6 seconds.

5. Valve closing time: When the working voltage is 5V, the time from open state to fully closed state is less than 6 seconds.

6. Flow rate: maximum flow rate 3M2/h

7. Working medium temperature: less than 95 degrees

1

[ad_2]